Abstract
Innovative technologies are required to mitigate the challenges of climate change. A reversible high-temperature heat pump (HTHP) − organic Rankine cycle (ORC) system can be used for effective utilisation of industrial waste heat in the lower temperature band <100 °C. The system can provide useful process heat for industrial processes by operating in HTHP mode or generating power in ORC mode. This paper presents the experimental investigation of the reversible system in both HTHP and ORC modes. A single scroll unit was selected for the compressor (HTHP) and expander (ORC) roles, keeping the system compact. A HCFO refrigerant, R1233zd(E), with a low GWP value, was chosen as the working fluid for both operating modes. When operated in HTHP mode, a maximum compressor overall isentropic efficiency of 73.4 % and a COPmech of 4.8 (ΔTlift,rside = 41 K, Tsf,ev,in = 60 °C) was obtained. In ORC mode, the maximum net power output was 512.4 W (Tsf,ev,in = 90 °C, rp = 2.3), overall cycle efficiency was 3.01 %, and overall isentropic efficiency of the expander was 54.6 %. The technical limitations encountered, and solutions put in place during the experimental testing campaign are discussed in detail.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.