Abstract
This paper presents an experimental investigation of a fuel processor consisting of a JP-8 autothermal reforming (ATR) reactor and a surrogate-fed CO-cleanup train. The CO-cleanup train, comprising a water−gas shift (WGS) and two preferential oxidation (PROX) reactors, was tested as an integrated reactor train. A finned-wall ATR reactor was examined for light-off behavior and for steady-state product distribution, upon which the CO-cleanup train was designed. The thermal and chemical transient analysis during catalyst ignition indicated that the fuel undergoes deep oxidation to CO2 and H2O until 80% of the catalyst bed is ignited, followed by a significant rise in synthesis gas production. The WGS and PROX reactors were tested individually with the objective of identifying operating regimes for maximum CO removal. The PROX reactor train, consisting of two identical reactors connected in series, reduced the CO concentration from 1% to less than 6 ppm. The PROX-1 and PROX-2 reactors were compared in order t...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.