Abstract

The paper explores the experimental results of the prototype compound parabolic trough made of mild steel and silver-coated selective surface. This prototype has been tested with top cover. The performance of the collector has been evaluated with two kinds of receivers coated with three types of black coatings. First receiver is of copper coated with black copper, second receiver is of mild steel coated with black copper and third receiver is of copper coated with black zinc. From actual field experiments, it has been observed that the efficiency of the system achieved with copper receiver coated with black copper is comparatively higher than the other two types of receivers. A simple regression analysis is used to correlate the thermal performance parameters of the system.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call