Abstract
Artificial roughness element with gap used to enhance the performance of solar air heater. Compared to the traditional smooth absorber plate and absorber plate with artificial roughness element without gap, the thermo-hydraulic performance (THP) of discrete artificial roughened solar air heater was found more. An experimental study of the heat transfer and fluid flow properties of the solar air heater was carried out using artificial roughness with an area in the absorbent plate. At present, discrete rib roughness in a double reverse arc manner has been used with variations in mass flow from 3000 to 14000 in the form of Reynolds number. The range of roughness parameters, such as the first used for the constant value of α of 600 and p/e from 6.67, 8.33, 10, 11.67 and the second used for the fixed value p/e of 8.33 along with the arc angle change, α of 300, 450, 600, 750 in the properties of heat transfer and fluid flow to achieve. These experimental results are important for applying an improved solar air heater.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.