Abstract This study aims to investigate and optimize the process parameter of similar metal weld joint between Duplex Stainless Steel and Duplex Stainless Steel. Plates of 2 mm thickness of DSS conforming to grade 2205 were butt welded using Gas Tungsten Arc welding, with Argon as shielding gas. Electrode to specification E 309LT-1 was used as filler metal. Test specimens were evaluated for tensile test and the values were observed as ultimate tensile strength 659 Mpa, yield strength 596 Mpa and the breaking load 23.74 KN. Objective of this work is to investigate mechanical properties and to optimize the process parameters to obtain higher tensile values by using Taguchi method. Voltage, Current and filler feed rate were chosen as a control factors in view of the impact on the input variables. Ultimate tensile strength was chosen as response variable to calculate the signal-to-noise ratio. Analysis of variance (Anova) method was adapted to identify the percentage contribution for all the factors and high important factor which is contributing for the optimum result.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.