Abstract

This paper presents the results of tests on a 1 10 scale model PCRV in the elastic range, in the cracked condition and in the ultimate loading condition. The linear and non-linear stress analyses and ultimate load assessment of the model are also presented. In the linear analysis, three-dimensional finite element methods with arbitrary arranging nodes were used, and in the non-linear analysis, three-dimensional (axisymmetric) finite element methods were used. The interaction of liner, prestressing cable, rebar and concrete solid were considered in both analyses. The ultimate load of the PCRV was calculated by using the yield line method. There was generally good agreement between the test results and theoretical predictions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.