Abstract
A gas turbine airfoil contains multiple coolant passageways. These passages usually have rib roughened wall surfaces in order to increase the heat transfer from the blade to the cooling air. Auxiliary power and compressed air is very valuable in a gas turbine, therefore low pumping power requirements are crucial. The thermal performance of three different coolant channel geometries with three different rib sizes was investigated. Heat transfer calculations were performed for Reynolds numbers ranging from 6,000 to 40,000. The performance characteristics were calculated through the use of the convective heat transfer coefficient and the friction factor. In this study, the most desirable characteristics are a high heat transfer coefficient and minimal pumping power requirements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.