Abstract

The paper presents the results of an experimental campaign conducted with the aim to evaluate the fire behaviour of unprotected and protected seismic elastomeric bearings installed inside an actual building. In particular, one unprotected and two protected natural rubber bearings were tested under the ISO 834 heating curve. The fire protection was made of blankets based on alkaline earth silicate wools (AES) of different thickness, i.e. 100 mm and 125 mm. The fire tests were performed by applying a constant vertical load equal to 900 kN to elastomeric bearings of diameter 400 mm, i.e. applied stress less than 10 MPa. The tests highlighted that the unprotected elastomeric bearing met the fire resistance requirement of 60 min before a loss of vertical load-bearing capacity owing to degradation of the mechanical properties at elevated temperature, whereas the protected elastomeric bearings could satisfy the fire resistance requirement of 90 min. A comprehensive description of the experimental outcomes, that also include the characterisation of the residual post-fire mechanical properties, is thoroughly reported in the paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.