Abstract
This paper presents an experimental evaluation of transmission length in hollow core slabs against 18 suggested equations in some codes of practice in addition to some equations from the previous literature. The experimental transmission length was predicted at 95% average mean strain (95% AMS) by measuring changes in strain after wire cutting on the near concrete face using both electric strain gauge and demountable mechanical strain gauges (DEMEC). The ratio between the measured transmission length and the value predicted using codes of practice equations varied from 1.0 to 1.26. On the other hand, the variation was 0.59 to 1.97 for the equations from the previous literature. The experimental results also confirmed the previous findings of non-linear prestress transfer over the transmission zone
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.