Abstract
The aim of this work is to experimentally evaluate three different compact branched heat exchangers, measuring, for every single device, the thermal efficiency and the pressure drop. The generality of the analysis of phenomena is enhanced by a comparison of the performance of different refrigerant fluids. In the first configuration, the channels have been designed, varying the inner diameter, to allow for an average constant flow speed throughout the exchanger. In the second one, the flow Reynolds number inside of the channels has been maintained constant. The last configuration is built according to the constructal diameter variation, as indicated in Bejan Constructal Theory. The exchanger manufacturing process is described in detail. The test bench has been assembled using a hot source (Heating Plate with a power of 500W) and a submersible pump, needed for the fluid recirculation, coupled with flowmeters, to control the mass flow rate within a specific range. The data obtained from several comparative tests have been analyzed, to determine the optimal solution for each refrigerant among the different exchangers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.