Abstract

This work presents an experimental evaluation of the removal efficiency of SO2 in a spray tower. The experiments were carried out in different conditions, varying gas velocity and using different sprays nozzles. The influence of the height of tower on the removal efficiency was evaluated through experiments inside spray tower. In this study was used two sets of five nozzles, with diameter of orifice of 2.4 and 3.2 mm, and only one nozzle with diameter of orifice of 5.6 mm. The results showed the influence of the gas velocity and L/G ratio in the removal efficiency, the influence of the gas velocity on the volumetric gas side mass transfer coefficient and the influence of the height of the tower in the removal efficiency.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.