Abstract
This paper describes an experimental program designed to verify the behavior of 3-wythe panels under later load and at the time of prestress transfer. The general flexural behavior of the 3-wythe panels was investigated using lateral load tests. Load-deflection behavior, degree of composite action, flexural strength, and horizontal shear of the panels under the action of a uniform pressure over the panel span were evaluated in this study. Fabrication of the panels for the lateral load tests revealed that cracking at prestress transfer was a concern. Thus, additional tests were performed to evaluate stresses at prestress transfer. These tests examine the actual behavior of full-scale, 3-wythe panels under the action of prestress force. Experimental results presented in this paper are compared with FEM analysis results. Descriptions of FEM analyses and models were given in a prior paper, and complete details of the work presented in this paper were provided in 2 other earlier papers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.