Abstract

This article deals with experimental investigation of air flow around in - line standing circular cylinders and influence of nearby standing hall on external wind pressure distribution. For vertical circular cylinders in a row arrangement only wind force coefficient is possible find in Eurocode. 1991-1-4. External wind pressure coefficient depends on wind direction and the ratio of distance and diameter b. Influence of nearby standing structure is not possible find in Eurocode. The series of parametric wind tunnel studies was carried out in Boundary Layer Wind Tunnel (BLWT) STU to investigate the external wind pressure coefficient in turbulent wind flow. We have compared the results of free in - line standing 3 circular cylinder and influence of hall on distribution of wind pressure at 3 height levels in turbulent wind flow and these results were compared with values in EN 1991-1-4. In this research, a series of parametric wind tunnel studies was carried out in Boundary Layer Wind Tunnel STU to investigate the effects of distance and roughness of cylinders in steady and turbulent wind flow.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.