Abstract

The fate of mono-dispersed fluorescein-tagged particles with nominal aerodynamic diameters 3 μ m and 14 μ m has been measured in a room-scale chamber under natural and forced mixing conditions. The mixing time scales were measured as the time to mixing of carbon monoxide tracer gas. In the forced mixing condition, 3-axis ultrasonic anemometry was used to determine the mean and fluctuating velocity for each vector component at 106 locations. Cumulative deposited fluorescein mass at 61 locations on the chamber floor showed size-dependent and mixing-dependent particle dispersion patterns. More uniform deposition was produced under conditions with relatively shorter mixing time scales, and longer particle settling time scales. A unique data set has been generated for the evaluation of particulate contaminant transport models.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.