Abstract

Abstract The current output from various common galvanic (sacrificial) anode geometries used in immersion service was experimentally determined. The results showed a specific functional dependence on exposed surface area and a scalable inverse relationship to the resistivity of the surrounding electrolyte medium. The use of this information as applied to cathodic protection design is also presented using three of the most readily available freshwater sacrificial anode metal alloys.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.