Abstract
We experimentally demonstrated and quantitatively evaluated a non-contact nanometer-displacement measurement using phase-diversity optical digital coherent detection implemented by a 90 ° optical hybrid and a narrow-linewidth probe laser without fine-tuning of optical path length difference (OPD). Combined with a comb filter, the system exhibits 99.99% linearity detection with a scale and resolution of approximately 7 nm and 2 nm respectively, as well as a wideband vibration of 5.85 MHz. We also experimentally analyzed the effect of noise arising from the OPD and demonstrated the detection of displacement down to 85 nm with a resolution of 24 nm at an OPD of 342 cm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.