Abstract

In the present study, an experimental comparative analysis of Air Breathe Direct Methanol Fuel Cells (DMFC) was conducted using two different flow field patterns, namely spiral and serpentine. The impact of flow field plates on cell performance, CO2 gas bubble behavior and pressure drop was examined at various mass flow rates and current densities. The experiments were conducted with the same hydraulic diameter and channel length for both flow field patterns, varying mass flow rates from 0.25 to 4 ml/min, and exploring reactant concentrations ranging from 0.25 M to 4 M. From the results it is observed that, for both the flow field patterns, pressure drop increases and CO2 bubble formation decreases with increase in mass flow rate. It is also observed that, under identical operating conditions, the serpentine flow field exhibits higher values for both pressure drop and peak power density compared to the spiral flow configuration. The study reveals that, the serpentine flow appears more efficient in terms of peak power density, while the spiral flow outperforms in terms of minimizing pressure drop under the specified operating condition.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.