Abstract

The effective length factors for steel solid round diagonals in all-welded communication towers are investigated in this paper to provide experimental basis for the relevant clauses in CSA Standard S37-01. The results of a total of 31 all-welded lattice tower specimens with three types of cross-braced diagonals are presented. The failure loads for these members were determined from the maximum axial strains measured during the tests. The effective length factors were then back-calculated from the experimental failure loads using the compressive resistance formulas. The test results showed that even the significantly lower effective length factors specified in CSA S37-01, compared to CSA S37-94, are still conservative.Key words: all-welded towers, communication towers, cross-bracing, effective length factors, solid round steel diagonals.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call