Abstract

The thermal performances of a PCM copolymer composite wallboard has been experimentally investigated in a full scale test room. The test cell is totally controlled so that a typical day can be repeated (temperature and solar radiative flux). Effects of the PCM are investigated comparing the results obtained with and without composite wallboards for three cases: a summer day, a winter day and a mid-season day. The results show that: (1) for all the cases tested, the decrement factor varies between 0.73 and 0.78 which is quite interesting for use in buildings and particularly for renovation; (2) the air temperature in the room with PCM lowers up to 4.2 ° C , the comfort enhancement is more important if the surface temperatures are also considered; (3) the PCM wallboards enhance the natural convection in the room and then there is no thermal stratification contrary to the room without composite; (4) the numerical experiments are fully described and can then be used to evaluate PCM numerical modeling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.