Abstract

It is common practice to use non-monolithic connections to connect the new flat slabs to the existing columns for upgrading the stories number of the existing buildings, despite the lack of design guidelines for the non-monolithic connection. Therefore, the current study evaluated four different techniques to connect the flat slabs with columns non-monolithically. The four systems were transferring shear force by shear dowels, transferring shear force and moment by welding dowels with the main flexural reinforcement, transferring shear force by steel bracket, and transferring shear force by concrete key-lock. An experimental study was conducted for five full-scale specimens tested under centric monotonic load and the results were compared to different codes’ expected capacities. Results showed that the four proposed techniques enhanced the punching shear capacity of the flat-slab. Moreover, the codes’ comparisons illustrated that the design codes had more reliable predictions for the monolithic connections rather than the non-monolithic ones.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.