Abstract
This paper deals with the experimental and theoretical evaluation of punching shear capacity of steel fiber reinforced concrete (SFRC) slab–column connections. Five experimental specimens with a thickness of 160 mm, different fiber volume contents (0, 1.0, and 1.5%) and different flexural reinforcement ratios (0.75 and 1.5%) have been tested. The experimental results were evaluated using a physical–mechanical model based on the critical shear crack theory (CSCT). The model has given a good approximation of experimental punching shear strengths. In general, tests have highlighted a significant increase in load and deformation capacity of fiber reinforced concrete slab–column connections in comparison with reinforced concrete connections.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.