Abstract

In this paper, a new honeycomb plate box-type hollow roof structure is prepared. The failure mode and mechanical properties of the box-type hollow roof structure were analyzed by bearing capacity test and numerical analysis. The validity of the numerical analysis model is verified by comparing the results of bearing capacity test with the results of the complete coordinated model and the coupled model analysis. The results show that the failure mode of the specimen is tensile failure of the surface plate of the honeycomb plate with strengthened frame and buckling instability of the plate near the joint. The box-type hollow roof structure has good ductility. The results of static analysis and nonlinear buckling analysis of the honeycomb plate box-type hollow roof structure are carried out by coupling model are more consistent with the results of bearing capacity test.