Abstract
A novel lap-spliced connection with ultra-high performance concrete (UHPC) was proposed to connect precast railway bridge column segments with footings or cap beams. Two 1:3 scaled specimens were tested under cyclic loads. Specimen PC-LS was a precast column with lap-spliced rebar connection and UHPC wet joints. Specimen CIP was a monolithic column as a reference specimen. The test results revealed that the plastic hinge region of the precast specimen shafted to the upper surface of the UHPC wet joint. The failure mode of the precast specimen was exhibited as the crushing of the core concrete and the buckling/fracture of the longitudinal rebars. Specimen PC-LS experienced larger lateral force, initial stiffness, comparable ductility, and energy dissipation compared to specimen CIP. Additionally, the validated finite-element (FE) models considering the bond-slip effect between concrete and reinforcements were developed. The parametric studies were carried out to further investigate the cyclic behavior of specimen PC-LS. Analytical results demonstrated that the variation of the compressive and tensile strength of UHPC showed little influence on the cyclic behavior of the precast segmental column, which indicated that UHPC with natural curing and lower volume content steel fibers could be used as the wet joint. The precast segmental column had similar lateral force and stiffness with the cast-in-place column when the lap splice length was 10 times of the rebar diameter.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.