Abstract
A typical large-scale, steel, multiplanar tubular XT-joint specimen was tested, with its in-plane and out-of-plane braces subjected to a total of 11 different load cases comprising the basic axial loading as well as axial loadings combined with in-plane-bending (IPB) and out-of-plane-bending (OPB) moments. The stress concentration factors (SCFs), strain concentration factors (SNCFs), and the SCF-to-SNCF ratio (S/N Ratio) at the potential hot spot stress locations were investigated. An average S/N Ratio of 1.16 was derived from all the test load cases. The SCFs at typical hot spot locations were also calculated using finite-element (FE) analysis. The good agreement between the numerical and the experimental SCF results confirmed the reliability of the numerical modeling of the XT-joint. In addition, the writers' SCF results were compared with Efthymiou's influence function (IF) method and the ones derived from the corresponding uniplanar T-/X-joints. A clearer understanding of the significance of the multi...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Journal of Structural Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.