Abstract

In order to study the problems of unreasonable airflow distribution and serious dust pollution in a heading surface, an experimental platform for forced ventilation and dust removal was built based on the similar principles. Through the similar experiment and numerical simulation, the distribution of airflow field in the roadway and the spatial and temporal evolution of dust pollution under the conditions of forced ventilation were determined. The airflow field in the roadway can be divided into three zones: jet zone, vortex zone and reflux zone. The dust concentration gradually decreases from the head to the rear of the roadway. Under the forced ventilation conditions, there is a unilateral accumulation of dust, with higher dust concentrations away from the ducts. The position of the equipment has an interception effect on the dust. The maximum error between the test value and the simulation result is 12.9%, which verifies the accuracy of the experimental results. The research results can provide theoretical guidance for the application of dust removal technology in coal mine.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call