Abstract
In this study, a novel solar hybrid air-gap membrane distillation and humidifier-dehumidifier desalination (AGMD-HDD) unit was designed and investigated. In this proposed system, photovoltaic panels were used as the source of electricity in the AGMD-HDD hybrid system. The present work was conducted to explore experimentally the hybrid system's performance within 12 months and simulated numerically using TRNSYS software. The simulated results were in good agreement with the measured values. The flowrate of produced purified water from the solar AGMD-HDD hybrid system were 21.29 kg/h and 11.76 kg/h in the summer and winter seasons respectively. The specific thermal energy consumption (STEC) varied from 60 kWh/m3 to 310 kWh/m3 in summer and 87.12 kWh/m3 - 605.2 kWh/m3 in winter. Freshwater cost estimation using the solar AGMD/HDH system showed a remarkable decrease in freshwater production up to USD 14.32/m3. The gained output ratio (GOR) and the system competence reached 5.33 and 91.03% in summer using a seawater flow rate of 600 kg/h. The total reduction in CO2 emissions was 32 tons in winter and 43 tons in summer seasons.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.