Abstract A novel turbocompressor test facility has been designed for helium–neon gas mixtures, and its specific features are presented. To account for the heat transfer originating from the motor coolant, a surrogate model has been derived. By combining these results with additional numerical ones, a similitude study is conducted by quantifying the individual effects and contributions on efficiency of the Reynolds number, tip Mach number, and specific heat ratio. Decoupling the effect of the different parameters shows that their respective contribution on efficiency variation is highly correlated with the Reynolds number actual value. The negative contribution of the tip Mach number and the positive effect of Reynolds number can be used to explain the efficiency variation with the increasing tip Mach number. Specific heat ratio variation leads to minor changes in polytropic efficiency except at low tip Mach numbers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.