Abstract

In this study, impingement air jet heat and flow characteristics of hexagonal finned heat sink which was named as OHS-2 were determined experimentally and analysed numerically by Ansys-Fluent CFD programme. The heat sink was optimized by using Taguchi method in the wind tunnel according to L18(21×37) orthogonal array in earlier study [1]. Therefore, the optimized heat sink was used instead of another heat sink. Six of most commonly used turbulence models in the numerical analysis of heat and mass transfer with impinging jets were examined and k-ɛ reliable turbulence model was chosen the most suitable for experimental study. The experimental and numerical studies were carried out for a heat sink with a nozzle diameter, two different Y/d distances, 6 different flow rates and 3 different fin heights. The variations of the Nu-Re and Cpx,y- l/(l0/2) were analysed and compared. Finally, heat transfer correlations were produced from experimental and numerical results of impingement jet heat transfer. Also the numerical and experimental results were observed to be in a good agreement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.