Abstract
The interaction of tip leakage flow and main flow in an axial flow pump can induce the tip leakage vortex, which causes the unstable flow and complex cavitation structures. In the present research, the modified shear stress transport k–ω turbulence model was utilized to predict the cavitating flow of the model pump under design and off-design conditions. Validations were carried out using high-speed photography techniques. Results show that the simulation results about cavitation performance based on the modified shear stress transport k–ω turbulence model agree well with the experimental results. Cavitation inception occurs more possible at part-load conditions, and with the increase of the flow rate, the starting point of tip leakage vortex gradually moves to the back edge of the blade chord. Both the sheet cavitation and the triangular cavitation cloud that formed in the blade tip grow in size and intensity gradually with the decrease of cavitation number. Distributions of the cavity area fraction and axial velocity show that the tip leakage vortex cavitation locates at the radial coefficient r* = 0.95–1.0 with peaks at about r* = 0.97, while the sheet cavitation is found at r* = 0.5–0.9 on the suction side (SS). The cavitation structures lead to a significant decrease in the axial velocity, especially in the tip region of the blade.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.