Abstract

Experimental data for velocity field, temperatures, and gas composition have been obtained from a 50 kW axisymmetric non-swirling natural gas fired combustion setup under two different settings. The reactor was constructed to simulate the conditions in the freeboard of a grate-fired boiler but under well-defined conditions. The experimental results are compared to computational fluid dynamics (CFD) modeling predictions, using the eddy dissipation model (EDM) as well as the eddy dissipation concept (EDC). The use of EDC allows for implementation of more advanced combustion schemes; we have tested the four-step global mechanism by Jones and Lindstedt (Combust. Flame 1988, 73, 233−249), and the 16 species and 41 reaction skeletal mechanism by Yang and Pope (Combust. Flame 1998, 112, 16−32). The CFD model captured the main features of the combustion process and flow patterns. The application of more advanced chemical mechanisms did not improve the prediction of the overall combustion process but did provide a...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.