Abstract
The demand of increasing pressure ratios for modern high pressure compressors leads to decreasing blade heights in the last stages. As tip clearances (TC) cannot be reduced to any amount and minimum values might be necessary for safety reasons, the TC ratios of the last stages can reach values notably higher than current norms. This can be intensified by a compressor running in transient operations where thermal differences can lead to further growing clearances. For decades, the detrimental effects of large clearances on an axial compressor's operating range and efficiency are known and investigated. The ability of circumferential casing grooves in the rotor casing to improve the compressor's operating range has also been in the focus of research for many years. Their simplicity and ease of installation are one reason for their continuing popularity nowadays, where advanced methods to increase the operating range of an axial compressor are known. In the authors' previous paper, three different circumferential groove casing treatments were investigated in a single-stage environment in the low-speed axial research compressor at TU Dresden. One of these grooves was able to notably improve the operating range and the efficiency of the single stage compressor at very large rotor TC (5% of chord length). In this paper, the results of tests with this particular groove type in a three stage environment in the low-speed axial research compressor are presented. Two different rotor TC sizes of 1.2% and 5% of tip chord length were investigated. At the small TC, the grooves are almost neutral. Only small reductions in total pressure ratio and efficiency compared to the solid wall can be observed. If the compressor runs with large TC, it notably benefits from the casing grooves. Both, total pressure and efficiency can be improved by the grooves in a similar extent as in single stage tests. Five-hole probe measurements and unsteady wall pressure measurements show the influence of the groove on the flow field. With the help of numerical investigations, the different behavior of the grooves at the two TC sizes will be discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.