Abstract

ABSTRACTSupersonic ejectors involve very complex phenomena such as interaction between supersonic and subsonic flows, shock trains, instabilities, which strongly influences the performance of supersonic ejector. In this study, the static pressure distribution along the ejector wall and Mach number distribution along the axis are used to investigate the internal flow field of supersonic ejector. Results indicate that when the back pressure is much less than the critical back pressure, there are two series of shock trains, and the change of the back pressure will not affect the flow field before the effective area section, so the entrainment ratio would remain constant. The second shock train moves further upstream and is combined with the first shock train to form a single shock train as the back pressure rises. When the back pressure is greater than the critical back pressure, the position of the shock train, the static pressure at its upstream and the entrainment ratio, will be affected. The “effective area section” in the mixing tube is obtained. The effective area section position moves downstream with the increase of the primary flow pressure, while it moves upstream with the increase of the secondary flow pressure. The entrainment ratio shows inversely proportional relationship with the effective section position. Besides, the first shock train length increases with the increase of primary flow pressure or secondary flow pressure. The critical back pressure represents direct proportional relationship to the first shock train length.