Abstract
The Algerian research reactor (Es-Salam) is a 15 MW heavy water reactor type, operating since 1992. It became essential to characterize the neutron field in the most useful irradiation positions, in order to guarantee the accuracy in the application of k0-neutron activation analysis (k0-NAA). Experimental value of the thermal to epithermal neutron flux ratio (f) and of the deviation of the epithermal neutron spectrum from 1/E shape (α) were determined using different methods. This work focuses the verification of Monte Carlo neutron flux calculation in typical irradiation channel. Comparison of the results for parameter f obtained experimentally and by Monte Carlo simulations shows good agreement in the irradiation channel studied. The difference between both results is about 2.08%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.