Abstract

The project of nuclear station LNPP-2 with a reactor power plant VVER type by electrical power 1200 MVt involves a number of new design solutions to increase of parameters of safety. The passive containment heat removal system and heat removal system via steam generators is including of number of such solutions. Passive heat removal system via steam generators (PHRS/SG) is assigned for remove of residual heat of reactors core to final heat absorber (atmosphere) through a secondary circuit at DEC accident. The system PHRS/SG duplicates cooling-down system via SG to final heat absorber in case of impossibility of realization of its design functions. Containment heat removal system (PHRS/C) is assigned for remove of residual heat from containment in accidents with heat-transfer emissions from primary circuit. PHRS/C duplicates functions of a spray system to reduce of pressure under containment in case of spray system failure. In the substantiation of passive security systems the complex in SPbAEP of computational and experimental analysis was executed, the main results of which are shown in the present report.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call