Abstract
The geometry of volute tongue is crucial in the design of Sirocco fans. The size of the volute tongue determines its relative position and distance from the impeller which affects the local flow characteristics and thus the aerodynamic and aeroacoustic performances of the fan. In this work, we performed experimental and numerical investigations on the effect of volute tongue radius on the aerodynamic and aeroacoustic characteristics of a Sirocco fan. The internal flow characteristics are analyzed and discussed in terms of the spatial distribution and temporal variation of pressure and streamlines, the pulsating behaviors of pressure both in the impeller and on the volute surface with emphasis in the volute tongue region, the variation of passage flow with the rotation of impeller and the aeroacoustic features of the fan. We conducted numerical simulations using both steady Reynolds-Averaged Navier-Stokes (RANS) and unsteady Reynolds-Averaged Navier-Stokes (URANS) approaches with realizable k-ε turbulence model with rotation effect correction and the results are compared against the experimental data to assess the prediction capability and accuracy in qualitative and quantitative manners. Experimental and numerical results show that as the volute tongue radius increases, the static pressure rises as well as the far-field noise of the fan and pronounced fluctuation of flow is observed within the whole impeller and volute; the reversed flow in the passage of the impeller is reduced and the high-pressure region is found to be moving towards the outlet of the volute. The decreasing radius also enlarges the size of the adverse pressure gradient (APG) region on the volute tongue which contributes to the formation of recirculating flow. The comparative RANS and URANS simulations reveal that both approaches produce generally consistent results regarding the time-averaged flow although the URANS data are much closer to those of the experimental ones. However, the fluctuating flow which is not capable to be modeled by RANS still dominates for the present configuration and thus URANS is necessary for the accurate prediction of the flow details.
Highlights
Sirocco fans, named as multi-blade centrifugal fans, are widely used in industrial and civil applications due to its small size, large flow coefficient and high pressure coefficient, while the Processes 2020, 8, 1442; doi:10.3390/pr8111442 www.mdpi.com/journal/processesProcesses 2020, 8, 1442 disadvantages of low static pressure and low efficiency have always restricted the development of the Sirocco fans
Fan obtained by unsteady Reynolds-Averaged Navier-Stokes (URANS) and compared with those obtained by Reynolds-Averaged Navier-Stokes (RANS) simulation and experiment
There is a certain degree of difference between RANS and URANS results, we find RANS usually over-predict the pressure at monitor-A and -F and the magnitude of over-prediction gets remarkable as the volute tongue radius increases
Summary
Named as multi-blade centrifugal fans, are widely used in industrial and civil applications due to its small size, large flow coefficient and high pressure coefficient, while the Processes 2020, 8, 1442; doi:10.3390/pr8111442 www.mdpi.com/journal/processesProcesses 2020, 8, 1442 disadvantages of low static pressure and low efficiency have always restricted the development of the Sirocco fans. The analysis and research of the internal flow of the Sirocco fans by means of reasonable and applicable approaches play a meaningful guiding role in further improving and optimizing the performance of the fans. The volute is one of the main components of the Sirocco fans which plays an important role in guiding the flow outside of the impeller and converting kinetic energy into pressure energy and has received wide extensive attention from many researchers. By controlling the volute tongue which determines the recirculation flow, Dilin et al obtained the velocity and pressure distribution under a wide range of azimuth angles [2]. The results show that the optimized volute improves the performance of the fan but the flow is unstable when the flow rate increases [3]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.