Abstract
Life tests were conducted at three different loads with three groups of 8.9 cm (3.5 in.) pitch diameter spur gears made of vacuum arc remelted (VAR) AISI 9310 steel. Life was found to vary inversely with load to the 4.3 and 5.1 power at the L10 and L50 life levels, respectively. The Weibull slope varied linearly with maximum Hertz contact stress, having an average value of 2.5. The test data when compared to AGMA standards showed a steeper slope for the load-life diagram.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.