Abstract

Embedded Through-Section (ETS) technique has gained a great deal of increasing interest in the shear strengthening of existing reinforced concrete members, which is based on using fibre-reinforced polymer (FRP) bars installed through predrilled holes into concrete via adhesive. One of the key issues associated with the bonding of ETS FRP bars to concrete is the debonding of FRP bar-to-concrete interfaces which leads to premature and brittle failure of strengthened members, particularly under elevated temperatures. However, little research has been conducted on the influence of elevated temperatures on the bond behavior between ETS FRP bars and concrete. This paper presents experimental and analytical evaluations of the bond response of ETS-ribbed glass FRP (GFRP) bar-to-concrete joints subjected to elevated temperatures. A total of 90 pullout specimens were tested to quantify the influences of the temperature, bar diameter, and concrete strength on the failure mode, load response and bond strength. An analytical model to reproduce the full-range debonding process of ETS-GFRP bar-to-concrete interfaces was presented, which allowed simultaneously considering both long and short embedded lengths, interfacial friction, and snap-back behavior. The load-slip response, stress field, and peak load were solved analytically, resulting in a closed-form solution for the critical length for snap-back and a non-closed-form solution for the effective embedment length. After an inverse analysis procedure was proposed for determining the bond parameters, the accuracy of the analytical solution was verified through comparisons with the self-conducted test results and existing experimental data. A new temperature-dependent bond strength model was also developed. The findings revealed a remarkable decline in the bond strength of up to 92.3 % as the temperature increased from 20 °C to 160 °C, with about 60–70 % of this degradation occurring close to the glass transition temperature (Tg) of the adhesive. At temperatures well above Tg, the bond strength decreased with the bar diameter and displayed insignificant improvement with higher concrete strength. The results also demonstrated that the proposed analytical approach and bond strength model can predict the bond response of ETS ribbed GFRP bars embedded in concrete with reasonable accuracy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.