Abstract
Dynamic response of single lap joints, subjected to a harmonic peeling load is studied theoretically and experimentally. In the theoretical part, dynamic response of a single lap joint clamped at one end and subjected to a harmonic peeling load at the other end is investigated. Adherents are modeled as Euler-Bernouli beams joined in the lap area by a viscoelastic adhesive layer. Both axial and transverse deformations of adherents are considered in deriving the equations of motion. The effects of adhesive layer thickness, mechanical properties and its loss factor on the dynamic response of the joint are investigated. Furthermore, effects of defects such as a void in the lap area on the dynamic response of the joints are studied. The results showed that frequencies where peak amplitudes occurred were little dependent on the adhesive loss factor. However, peak amplitudes reduced for joints with a higher adhesive loss factor. Furthermore, the results indicated that for the joint geometries and properties investigated the system resonant frequencies were not affected by the presence of a central void covering up to 80% of the overlap length. In the experimental part, single lap joints were fabricated using 6061-T6 Aluminum. Adherents were joined together using Hysol EA 9689 adhesive film. Joints with various central voids were manufacture by removing adhesive film from the desired area of lap joints prior to bonding adherents. Dynamic responses of the joints were investigated using the hammer test technique. The system response was measured using both an accelerometer and a non-contact laser vibrometer. The natural frequencies of the joints obtained by using the laser vibrometer were very close to those obtained theoretically. However, natural frequencies obtained by using an accelerometer depended on the accelerometer location in the system, which was attributed to its mass contribution to the over all system mass. A central void covering less than 80% of the overlap length had little effect on the system resonance frequencies. This was in agreement with the theoretical results. In contrast, total system-damping ratios were a function of the void size. Joints without a void exhibited higher damping.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.