ABSTRACT This paper is devoted to the investigation into the lateral performance of cross-laminated timber (CLT) shear walls with different construction methods (i.e., platform construction and balloon construction). Quasi-static cyclic tests were conducted on four CLT shear wall specimens. The hysteretic performance, failure modes and contribution of deformability components of the specimens were obtained and compared. Furthermore, analytical prediction models were developed for the CLT shear walls with either platform or balloon construction method. The proposed models were validated by test results and can serve as convenient tools for estimating the lateral load resisting performance of CLT shear walls.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.