Abstract

Using an experimental setup, the series configurations (SC) and the parallel configurations (PC) of the PV cell connection are studied to compare their performance under the condition of partial shading s. The performance of the configurations is evaluated by comparing the open-circuit voltage, the short-circuit current, the maximum power point (MPP), the voltage and current corresponding to MPP, and the Fill Factor (FF). The variations of the series resistance and the shunt resistance of a PV module under different irradiance levels are also determined by considering the effect of thermal voltage. Finally, a comparison between the performance losses in the different configurations is presented. The results of this study show that the parallel configuration has the best performance under the conditions of partial shade in the context of this work.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.