Abstract

Under different Electronic Expansion Valve (EXV)opening degree at the fixing frequency of 50hz of the compressor,we had test the system performance. When the cooling refrigerant influence to the PV module and the heating air influence to the collector/evaporator reached the balance,the photoelectric efficiency achieved the maximum.When the EXV opening degree fixing, with the raising of the solar radiation, the compressor power values appeared oscillation,and the oscillation was especially evident when the EXV at the maximum opening degree. So we put forward the PV/T-SAHP system stability principle.At the same time,we found that the key of the PV/T-SAHP research is to discover the relation between the solar radiation and the superheat of collector/evaporator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.