Abstract

The current paper presents the results of the experimental analysis to assess and optimize the twin-screw compressor’s efficiency by varying the volume ratio. The experimental tests are conducted on the compressor's test bench, with a dedicated automation system inside the control console. The control and monitoring software allows parameter recording for subsequent visualization, data curation, and post-processing. The evaluation of screw compressor's performance requires a simultaneous analysis of the thermodynamic and flow processes, both of which depend on the compressor’s geometry. The obtained volumetric and adiabatic efficiencies are good, with values over 0.88 and 0.69, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.