Abstract

This report deals with the description of development of waterproof steel fibre reinforced concrete (suitable for concrete lining of tunnel constructions in particular) in cooperation with the concrete supplier. With regard to newly released documents, two formulas of waterproof concrete supplemented with steel and polypropylene fibres were suggested. The formulas were designed according to different approaches (standards / Austrian Directive), and they differ only in various weight doses of the individual components. With regard to the general requirements for the tunnel lining (fire resistance tests, chemical stability, strength, impermeability and adhesion), strength and plastic properties, durability parameters (depth of penetration of water under pressure, depth of penetration of standing water, frost resistance, resistance of cement concrete surface to water and defrosting chemicals, depth of penetration of chloride) and the resistance to extreme thermal stress were determined in both the formulas. Standardized tests and non-standard testing have been completed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.