Abstract
This paper presents a study of power quality problems created by a UHP electric arc furnace (EAF) operation at power system. We are analyzing an electric arc furnace of 100 t capacity used for steel melting, and the related steel treatment installation. The measurements have been made using the CA8334 three-phase power quality analyser. Experimental results show that the EAF are a substantial source of electric disturbances, such as voltage fluctuations, flicker, harmonics, and unbalance between phases. Improvement of the energetic performances of an electric arc furnace imposes a careful technical and economical analysis, for choosing the possible solutions for balancing the load on phases, improving the wave forms (current and voltage) and improving the power factor.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.