Abstract

Abstract This paper presents the experimental study of eccentrically loaded reinforced concrete columns with an added 35 mm self-compacting concrete jacket attached to the column’s most compressed face using wedge bolts. Nine columns with a 2000 mm height were tested under compression and one-way bending until failure. Columns were denominated as original column (PO) with a cross section of 120 mm x 250 mm; reference column (PR) with a cross section of 155 mm x 250 mm, and seven columns with an initial cross section of 120 mm x 250 mm and later reinforced by the addition of 35 mm self-compacting concrete layer and various configurations of wedge bolts. Except for the original column PO, the columns were submitted to a 42.5 mm load eccentricity due to the added concrete layer at the compressed face. Although failure of the wedge bolts did not occur, it was not possible to prevent detachment of the added layer. The results indicate that it is possible to structurally rehabilitate reinforce concrete columns with the use of the strengthening methodology used in this research, resulting in average ultimate load capacity gains of 271% compared to original column’s ultimate load.

Highlights

  • A column failure can lead to the failure of part or the entire structure, which is an undesirable fact to any structural engineer

  • This paper presents the experimental study of eccentrically loaded reinforced concrete columns with an added 35 mm self-compacting concrete jacket attached to the column’s most compressed face using wedge bolts

  • Columns were denominated as original column (PO) with a cross section of 120 mm x 250 mm; reference column (PR) with a cross section of 155 mm x 250 mm, and seven columns with an initial cross section of 120 mm x 250 mm and later reinforced by the addition of 35 mm self-compacting concrete layer and various configurations of wedge bolts

Read more

Summary

Introduction

A column failure can lead to the failure of part or the entire structure, which is an undesirable fact to any structural engineer. Several causes can lead to a reinforced concrete column failure: imprudence, negligence, neglectfulness in design or construction; construction flaws; deterioration due to attack by aggressive agents; lack of preventive or corrective maintenance; incorrect structural use, etc. Increasing the concrete cross section by using a concrete jacket, which may include additional steel reinforcement, is a common technique for structural repair and rehabilitation used in Brazil. This experimental research of retrofitted columns will help structural engineers and other professionals with more scientific knowledge to deal with this situation in a safer and more economical way. A substrate surface preparation using waterblasting and the installation of wedge bolts, with different diameters and positioning, were used to avoid detachment of the added concrete layer and to increase bond with the substrate

Objectives
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call