Abstract
The performance of a double tube heat exchanger with V-cut twisted tape inserts (VCTT) and phase change material (PCM) dispersed nanofluid is investigated experimentally. The three water-based Al2O3, PCM, and Al2O3+PCM nanofluid with different concentrations (0.01-0.1% vol.) are used. The impacts of different geometric parameters, i.e., twist ratio (TR), depth ratio (DR) and width ratio (WR) of VCTT inserts on Nusselt number (Nu), friction factor (f) and entropy generation are examined. The outcomes expose that Nu and f increase as particle concentration increases and twisting ratio decreases. A higher Nu and f are generated by a higher DR or a lower WR. In all cases, the entropy generation of nanofluid is found to be lower than that of water. For all working fluids, a rise in TR, a fall in DR, and a rise in WR increases overall entropy generation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Vehicle Structures and Systems
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.