Abstract

Flow measurement and control in open channel system for lateral flow is important to support the system management. The flow characteristics of combined side weir-gate are complicated due to changes in flow conditions along the side weir-gate section. Experimental investigation of the flow characteristics of both weir and sluice gates is crucial for predicting the flow through a combined side weir-gate structure. Although weir-gate structures are widely used for frontal flow in hydraulic structures, the same is not true for lateral flows. In this study, 650 laboratory tests were conducted to determine the flow characteristics of combined side weir-gate for subcritical flow, and the experimental results were analyzed to determine the effect of these characteristics and weir-gate geometry on discharge capacity. Interaction factor of combined side weir-gate is a function of the upstream Froude number, the ratio of gate opening to upstream flow depth, the ratio of distance between the top of the sluice gate and the weir crest to gate opening, the ratio of weir and gate length to upstream flow depth, and the ratio of weir and gate length to main channel width. Consequently, more discharge is passed through combined side weir-gate compared to side weir and sluice gates. The empirically derived equations for the discharge of combined side weir-gate show good compatibility with the experimental data.