Abstract

AbstractThe paper presents the results of the Osterberg load tests performed at Belgrade Waterfront test site. Test results enabled evaluation of side friction and end bearing of the limestone/marlstone formation otherwise difficult to access. Mobilized side friction is several times larger than the side friction commonly used in design by practitioners for the large diameter drilled shafts. High pressure O‐cells manage to achieve 60 MN load (30 MN in each direction) which is significantly higher than specified design load.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.