Abstract

In order to estimate the accuracy of calculation methods such as empirical formulas and Monte Carlo codes for neutron and gamma ray fluxes through a labyrinth connected with a room having a Cu target irradiated by 68-MeV-proton, experimental analyses are carried out. As results of the analyses, the followings are obtained. (l)The MCNP calculation is applicable to estimation of neutron and gamma ray dose equivalent rates in the labyrinth, although cross sections in the process of neutron thermalization and gamma ray production cross section should be modified for more precise estimation. (2)The empirical formulas are useful for estimation of neutron dose equivalent rate. However, an additional safety factor of 2 should be required to apply to the estimation of total dose equivalent rates, because the contribution of gamma ray dose equivalent rate increases with the distance in the labyrinth and becomes comparable to that of neutron dose equivalent rate at the distance longer than 20 m.