Abstract

The current density on the collecting plates were measured of 12 kinds of common discharge electrodes matched C480 and ZT24 collecting plates. The effect of different discharge electrodes and setting manners on the experiment results was discussed with two parameters of average current density and relative standard deviation. The distributins of electric potential and electric field strength were calculated by using finite element method when V serial discharge electrodes matched ZT24 collecting plates. Combining the results of the experiments and numerical calculation, the paper analyzed the effect of electric field strength on the corona current.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.